Further specifications:
- Connection A: 10 mm pipe fitting
- Connection B: 10 mm pipe fitting
- Angle: 90°
Note: When fitting a cutting ring union with copper or aluminium pipe, always use a reinforcement sleeve! For aluminium pipe, use a steel reinforcement sleeve!
Safety and warning instructions
Installation by qualified personnel only: Installation must only be carried out by qualified personnel to ensure a secure connection.
Ensure compatibility: Before installation, check that the fitting is compatible with the pipe materials used (copper or aluminium).
Use a reinforcement sleeve: When installing with copper or aluminium pipes, a suitable reinforcement sleeve must always be used. For aluminium pipes, use only steel reinforcement sleeves.
Carry out a pressure test: After installation, a pressure test in accordance with the applicable regulations is required to ensure the connection is leak-tight.
Regular maintenance: Check the fitting regularly for wear, corrosion and leaks, particularly in safety-critical applications.
Observe operating limits: Only use the fitting within the specified pressure and temperature ranges in accordance with DIN standards.
These instructions are for your safety and to ensure the reliable operation of your liquefied gas system.